Mains pressure hot water cylinders

 
Mains pressure units supplied via Newark copper cylinders can be divided into:
  • Unvented mains pressure cylinders.
  • Thermal store cylinders.
 
 
Thermalstore

Available both in cylinder and combination tank form the thermalstore provides a pressure hot water service direct from the main. It achieves this by operating in the reverse way to the conventional system. The unit is heated up usually directly from the boiler or via immersion heaters and the heat energy store thus provided is used to instantaneously heat mains fed cold water passing through a heat exchange coil.

 
 
  Fitted with a matrix comprising a filter/strainer, expansion vessel and thermostatic blending valve the unit is capable of providing hot water at mains pressure at temperatures suiting individual requirement.

For optimum efficiency the hot water store capacity of these units should not be less than 140 litres.

 
 
Un-vented mains pressure system

Fed directly from the mains the un-vented system provides an efficient pressure hot water service. Whilst at the same time removing the need for a cold water storage tank and secondary cold feed and vent. Supplied in indirect or electrically heated form the un-vented cylinder usually comes complete with all necessary control valves and fittings and ready for installation. Installation must be by a competent person and the unit must be commissioned by a "certificated" fitter.