Sanisplit specification & selection guide

 
 
 
 
SANISPLIT selection guide
  • Use the chart above to select the correct unit for your application.
  • Units 1-3 only; are suitable for WC waste, note the large outlets on the drawings below.
  • Units K2 + K3 are pumping units suitable for waste water only.

Note that the top 40mm outlet at the rear of the unit is the main waste, which needs to be taken to the soil stack, the remainder are inlets from the appliances or sanitary ware. These inlets can be plugged if not required.

See pipe run drawings in the ' ability to remove the waste products whilst keeping the pipe runs as aesthetically pleasing as possible' section for further detail.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   
   
Specifications  
   
Power supply 230v ac
Power 600W
Electrical absorption 3A
Frequency 50 Hz
Revolutions per minute 2700
Protection class IP 55
Max elevation head 7 m
Max capacity 270l/min
Service Intermittent
Sewage water temperature <100°C
Condenser 10µF/450V
   
Sanisplit complies with the following standards:
Directive CE 89/392 - 89/336 - 73/23 - 93/68
 
 
Electrical connection
  • SANISPLIT requires a 230 v ac 50Hz single phase supply (U.K. specifications).
  • The appliance must not be connected to a conventional plug & socket.
  • SANISPLIT must be wired into a fused unswitched fixed wiring connector fitted with a 5A fuse.
  • SANISPLIT is double insulated and has earth connections.
 
 
 